Manual - TC.P Quadro
Q) Configuration 4
2016-08-05
317/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
25-7
Q6
Invalid CANmp
configuration of the
data type of a sig-
nal.
The CANmp configuration of the
data type of a signal is invalid.
An invalid data type is configured.
Configure a valid data type. Valid data types can
be found in the CANmp manual.
25-8
Q7
Invalid CANmp
configuration of the
scale factor of a
signal.
The CANmp configuration of the
scale factor of a signal is invalid.
An invalid scale factor is config-
ured.
Configure a valid scale factor. Valid scale factors
can be found in the CANmp manual.
25-9
Q8
Invalid CANmp
configuration of the
start bit of a signal.
The CANmp configuration of the
start bit of a signal is invalid.
The configured start bit is occu-
pied by another signal.
An invalid start bit is configured.
Check if the start bit is occupied only by one sig-
nal.
Configure a valid start bit. Valid start bits can be
found in the CANmp manual.
25-10 Q9
Invalid CANmp
configuration of the
CAN ID of a mes-
sage.
The CANmp configuration of the
CAN ID of a message is invalid.
The CAN ID is configured as a 29
bit identifier.
Configure the CAN ID as an 11 bit identifier. A
configuration of the CAN ID as a 29 bit identifier is
not supported.