Manual - TC.P Quadro
TopControl application
2016-08-05
232/330
V04.52
6
3
4
2
1
Fig. 138
Overview of <ADJUST 1> tab.
<ADJUST 1> tab
– parameter overview
1
Analog reference inputs,
group
Adjustment of the analogue inputs on interface X105 for voltage, current,
power and internal resistance. The maximum and minimum signal level on the
analogue input X105 is calibrated using the gain and the offset.
The indication on the right shows the numerical value actually measured.
2
Measurements,
group
Adjustment of the indication for the voltage and current measured value ac-
quisition indication via the arrow buttons.
The related actual value is indicated on the right.
3
Analog outputs,
group
Adjustment of the analogue outputs on interface X105 for voltage and current.
The maximum and minimum signal level on the analogue output X105 is cali-
brated using the gain and the offset.
The “Manual D/A control” check box switches on the manual calibration. I.e.
the “Voltage” and “Current” values are output on the analogue outputs.
4
Store settings,
button
Settings made on the <ADJUST1> tab are permanently saved. The actual
parameter set is saved from the RAM to the flash PROM in the TopCon power
supply.
Table 139 Overview of the <ADJUST 1> tab.