Manual - TC.P Quadro
6) Communication
2016-08-05
284/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
7-12
6B
TC.LIN CAN error
General error on system CAN con-
nection.
Communication error.
Reattach cable,
acknowledging the error via master,
device restart system.
Further counteraction CF. 60) / 61)
7-13
6C
RS232 Watchdog
error
Timeout in optional internal watch-
dog for RS232 interface
RS232 communication failed
No watchdog reset command was
sent to the device, within the con-
figured timeout time (needs to be
re-sent periodically while watch-
dog enabled).
Serve watchdog more often
Check Communication line
7-14
6D
IBC receive com-
munication error
Internal error on communication with
IBC board
Contact customer support
7-15
6E
IBC transmit com-
munication error
Internal error on communication with
IBC board
Contact customer support
7-16
6F
IBC Talk timeout
Internal error on communication with
IBC board
Contact customer support