Manual - TC.P Quadro
TopControl application
2016-08-05
225/330
V04.52
6
fast load change. The value should not be selected too small, as otherwise the
regulation will be poor.
<CONFIG> tab
– parameters (continued)
5
Slopes,
group
Ramps for limiting the set value slope, these do not change the set values and
have no effect on the controller.
With the internal function generator the ramps are used to limit the rate
change of the function.
Voltage slope at startup: (Ramp)
𝑆𝑡𝑒𝑖𝑔𝑢𝑛𝑔 =
𝑑𝑈
𝑑𝑡
with “VOLTAGE ON”
Voltage slope: (Ramp)
𝑆𝑡𝑒𝑖𝑔𝑢𝑛𝑔 =
𝑑𝑈
𝑑𝑡
Current slope at startup: (Ramp)
𝑆𝑡𝑒𝑖𝑔𝑢𝑛𝑔 =
𝑑𝐼
𝑑𝑡
with “VOLTAGE ON”
Current slope:
(Ramp)
𝑆𝑡𝑒𝑖𝑔𝑢𝑛𝑔 =
𝑑𝐼
𝑑𝑡
6
Slave characteristics (Matrix configuration),
group
Parameters for the optimisation of the control behaviour in multi-unit opera-
tion.
Can only be set on the master device in the multi-unit system.
Allowed slave voltage error
1
Entry of the deviation allowed in [%]
from the set value for the output voltage.
Allowed slave current error
1
Entry of the deviation allowed in [%]
from the set value for the output current.
Turn off slaves on no-load
If selected:
If a load is not connected,
the slaves are shut down.
Master device remains in operation.
7
Buttons
<System Configuration...>,
button opens a new window
The “Multi-module system configuration” window opens to make settings for
the multi-unit system. See Fig. 135, page 227
<Store settings>,
button
Settings made on the <CONFIG> tab are permanently saved. The actual
parameter set is saved from the RAM to the flash PROM in the TopCon
power supply.
<Refresh display>
The indication on the tab is manually refreshed.
Table 134 Parameters on the <CONFIG> tab.
1
Before an error message is generated