Function Sequence
Fig. 94
Settings for the individual function sequences
Function Sequence
– DISPLAY 31
1
Used FnBlocks,
menu item
Function blocks selected here have a direct effect on the indication in the Dis-
play mode. (see especially DISPLAY 2).
Possible selections:
none:
All function blocks are deactivated.
Voltage
:
Voltage function block is active.
Current:
Current function block is active.
Power:
Power function block is active.
U+I:
Voltage and current function blocks are active.
U+P:
Voltage and power function blocks are active.
I+P:
Current and power function blocks are active.
U+I+P:
All function blocks are active.
2
Trigger,
menu item
Event that triggers the function block selected in
-1-
:
VoltageOn
:
As soon as device output is switched live
Manual
:
Manual triggering via TopControl or HMI/RCU
via
-6-.
Pin on X105:
As soon as there is a high level on pin 19 on interface X105.
3
FnSeq End,
menu item
On continuous repetition
-4-
FnSeq End has no significance.
Selection of the output setting that is present on the output after the end of a
function sequence:
VoltageOff
The output is electrically isolated.
Hold level
Last set values in the function block are present on the out-
put.
Std. setvalues
The set values on the active interface are present on the
output.
4
# Repetitions,
menu item
Number of times a function block is repeated.
Value range:
0
– 65000; 0
≙ Continuous; default: 0
The table is continued overleaf.
Function Sequence page 1
Used FnBlocks
Trigger
Fn.Seq End
# Repetitions
current
at VoltageOn
Hold level
0
Trigger now
Repeat delay
0.00 s
Function Sequence page 1
Used FnBlocks
Trigger
Fn.Seq End
# Repetitions
current
at VoltageOn
Hold level
0
Trigger now
Repeat delay
0.00 s
1
3
5
2
4
6