Manual - TC.P Quadro
F) Miscellaneous
2016-08-05
308/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
16-14 FD
AC-Switch error
Error in the optional external switch
bridge (simple variant with contac-
tors).
See software documentation
V11.09.00+.
See software documentation V11.09.00+.
16-15 FE
AC-Bridge error
Error in external TopCon bipolar
switch (TopCon option ACLF).
See manual for bipolar switch
ACLF.
See manual for bipolar switch ACLF.
16-16 FF
FIFO queue for
actual values full
Buffer overflow while synchronising
actual values in networked opera-
tion.
Subsequent error of a CAN com-
munication error (cf. group error 6)
Cf. group error 6)