9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
14-8
D7
Number of devices
in parallel config.
does not corre-
spond with the
given value
The number of devices in parallel
circuit does not match with the sys-
tem configuration.
The module IDs are badly config-
ured.
Consult manual to reconfigure module IDs to
match the requirements.
14-8
D7
Number of devices
in parallel config.
does not corre-
spond with the
given value
The number of devices parallel cir-
cuit does not match with the system
configuration.
default setting differs from the
actual number of modules in serial
or parallel connection.
Connecting the same number of devices as speci-
fied.
Adapt the Master settings to the actual number of
devices.
14-8
D7
Number of devices
in parallel config.
does not corre-
spond with the
given value
The number of devices in serial or
parallel circuit does not match with
the system configuration.
One slave at minimum was not
detected as a result of a commin-
cation or login error
Cf. 6) and C).
14-9
D8
All slave ID's or
addresses (RSC
on) have to be
numbered without
a gap
The module IDs or addresses (RSC
on) aren’t numbered consecutively
without gap.
The Module IDs or addresses
(RSC on) aren’t numbered con-
secutively without gap. Refer to
section “network” in manual for
explanation of “without gap” (e.g.
in parallel connection the expres-
sion “without gap” means that IDs
= 00h, 10h, 20h, … are used.) The
value 'ui-
CAN_MaxNumModuleParallel'
must be set identically in all mod-
ules. default value: 8.
The module ID according the manual and the de-
sired configuation are set correctly.
14-10 D9
All HMI/RCU ID's
have to be num-
bered without a
gap
The HMI IDs aren’t numbered con-
secutively without gap.
From HMI firmware V5.15.00 the ID
have to be only unique
The HMI IDs aren’t numbered
consecutively without gap.
All HMI IDs must start with 01 and must be num-
bered consecutively without gap.
14-11 DA
Number of slaves
does correspond
with the given val-
ue
The total number of devices doesn’t
match the default.
Cf. D6) and D7).
Cf. D6) and D7).