Manual - TC.P Quadro
Technical data
2016-08-05
40/330
V04.52
3
Analogue outputs
Configuration
Quantity 2, can be configured to a certain extent, sin-
gle ended
Input voltage range
0
– 10 V
DC
External output impedance
Min. 1 k
Ω
Reference ground
Common for all analogue outputs
Isolation in relation to
controller and earth
125 V
Physical connections
On X105: pin 4,16
Table 26
Analogue outputs on the interface X105.
Further information: chapter 3.3.3.2, page 74.
Reference output
Configuration
Quantity 1
Output voltage
10 V
DC
Output current
Max. 10mA
Reference ground
Common with 24 V control voltage
Physical connections
On X105: pin 6
Table 27
Reference output on interface X105.
Further information: chapter 3.3.3.2, page 74.
Digital inputs
Configuration
Quantity 3, can be configured to a certain extent
Input voltage active
10
– 28 V
Input voltage inactive
0
– 2 V
Input impedance
4.7 k
Ω
Isolation to earth
125 V
Physical connections
On X105: pin 18, 19, 20
Table 28
Digital inputs in the interface X105
Further information: chapter 3.3.3.6, page 77.