Manual - TC.P Quadro
TopControl application
2016-08-05
192/330
V04.52
6
“Store/Load Function Sequence” window (continued)
5
<Store>,
button in the “Store Function Sequence” window
Saves the actual function sequence in the sequence number
-10-
given
(1...1000).
The content of
-8-, -9-, -10-
is used for the save.
If the sequence number exists:
Confirmation prompt as to whether the existing “Function Sequence” is to
be overwritten.
<Load>,
button in the “Load Function Sequence” window
The button is activated by selecting a function sequence on the list
-1-.
(Se-
lecting: click using the left mouse button)
The selected function sequence is loaded from the non-volatile memory
in the TopCon power supply to the TopControl application.
The “Load Function Sequence” window is closed at the end
loading process.
All parameters loaded are indicated on the <FUNCGEN> tab
and the curve shown in the preview.
6
Cancel,
button
Closes the dialog box and has the following effect:
Settings for remove autoload are retained.
Settings for set for autoload are retained.
Function sequences are not loaded.
Function sequences are not saved.
Function sequences deleted remain deleted!
The changes made must be made known to the TopCon power supply. On the
<CONTROL> tab click the <Store settings> button, see Fig. 107, page 184.
7
<current date/time>,
button
This button sets the actual date and time; values can also be modified manu-
al
ly in the “Date” and “Time”
-8-
boxes.
8
Date/Time,
text box
Date and time entry can be edited manually or generated automatically via
-7-
.
9
Name,
text box
Manual label entry for the function sequence.
Label length: maximum 30 alphanumeric characters.
10
Seq.Nr,
text box
Entry of the function sequence number.
Entry: numeric; value range: 1
– 1000
In case of duplicate numbers, a message appears on saving.
Table 111
Parameters in the “Store Function Sequence” and
“Load Function Sequence” window.
Use e.g. the key data for a curve to label a function sequence. If there
are several curves on the list
-1-
you will then be able to identify the
characteristics of the curve from the label.