9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
29-9
U8
RSC: Invalid ModuleID or ModuleAd-
dress in CAN-Bus from a Sub-System
RSC configuration failed
on at least one Sub-
System
Subsequent error of a login or configu-
ration error within a Sub-System
Configuration file not valid or does not
match with given system
Check with the activated option
TC.RSC, ìf the module ID 'AL' is
counted upwards without any gap and
the ID 'AH' = 0 is set.
Check for other errors, which refer to a
login or cofiguration error.
Check,if the selected configuration file
matches to the system topologie.
Contact customer support
29-10 U9
RSC: SwitchboxID's from Sub-
Systems not equal
RSC: Wrong switchbox-
ID in a
Sub-System
SwitchboxID in a Sub-System is 0 or
not equal to the other Sub-Systems, or
RSC not enable
Contact customer support
29-11 UA
RSC: Invalid Sub-SystemID or Sub-
SystemAddress
RSC: Wrong Sub-
System ID or Sub-
System address
Wrong Configuration-file or Sub-
SystemID
Check the Sub-System ID's with Top-
Control.
Contact customer support
29-12 UB
TC.MAC Optionboard not installed
MAC Optionboard not
installed but device is
configured as MAC or
MAC-Sub-System
Hardware problem or device configu-
ration wrong
Contact customer support
29-13 UC
Virtual TC.LIN ID invalid
Virtual TC.LIN ID is out-
side of the allowed
range.
Virtual TC.LIN device not set on value
between 0 and 7 (including 0 and 7).
Use TopControl connected to Virtual
TC.LIN device to set Virtual TC.LIN ID
to a value between 0 and 7 (including 0
and 7).
29-14 UD
Virtual TC.LIN ID not unique
Virtual TC.LIN ID exists
more than once.
The virtual TC.LIN ID in total system
have to be a unique (value: 0...7)
Replace twice-assigned virtual TC.LIN
IDs.
29-15 UE
Virtual TC.LIN not allowed in series
configuration
Virtual TC.LIN in series
operation is not allowed.
Operating with virtual TC.LIN in series
configuration.
Disable the virtual TC.LIN functionality
or change the configuration from series
to parallel in MAC (use TopControl).
29-16 UF
Not all Sub-Systems are capable of Q4
All Sub-Systems must be
of the same type (GSS
or not).
Not all Sub-Systems are the same
type (GSS or not).
Only connect GSS or Non-GSS Sub-
Systems.