Internal system communication
2016-08-05
142/330
V04.52
5
5.3.6.
Multi-unit system and TopControl application
Only the master is configured in the multi-unit system using the Top-
Control application.
Necessary conditions for configuration:
The master device in the multi-unit system must be connected to
a PC on which the TopControl application is running.
CAN connection to all devices in the multi-unit system see chap-
ter 5.3.3.1, page 136.
Procedure for multi-unit system configuration using TopControl
3
4
1
2
Fig. 77
Setting up multi-unit system using TopControl
On the <CONFIG>
-1-
tab press the
<System Configuration...>
-2-
button.
The “Multi module system configuration”
-3-
window opens.
Set the parameters for the multi-unit system.
For further information on the meaning and entry of the parame-
ters see chapter 6.4.7.5, Table 136, page 228.
Accept your entries using the <OK>
-4-
button.
A message appears with the rest of the procedure.
Set up the addresses of all the devices in the multi-unit system,
as per chapter 5.3.3.2, page 137.
Restart all devices to complete the multi-unit system
configuration. During this process switch back on all devices
within 10 s. The master device last.