Manual - TC.P Quadro
HMI and RCU
2016-08-05
166/330
V04.52
6
VLS settings
– page 2
Fig. 96
VLS settings page 2
– DISPLAY 32
VLS settings page 2
– DISPLAY 32
1
Upper limit or Lower limit,
menu item
1
[V], [A], [kW]
Whether the upper limit or lower limit can be entered depends on the function
selected on VLS page 1 (DISPLAY 24).
See Table 89, page 165.
Input range:
Voltage
1
:
-2*U
Max
– 2*U
Max
Current
1
:
-2*I
Max
– 2*I
Max
Power
1
:
-2*P
Max
– 2*P
Max
2
Upper hysteresis or Lower hysteresis,
menu item
1
[V], [A], [kW]
Whether the upper hysteresis or lower hysteresis can be entered depends on
the function selected on VLS page 1 (DISPLAY 24).
See Table 89, 165.
Value range:
Voltage
1
:
-2*U
Max
– 2*U
Max
Current
1
:
-2*I
Max
– 2*I
Max
Power
1
:
-2*P
Max
– 2*P
Max
3
Act--> inact delay,
menu item [ms]
Delay from the active to the inactive state.
Value range:
0 ms
– 3600 ms; step width: 0.1 ms; default: 0 ms.
4
Inact--> act delay,
menu item [ms]
Delay from the inactive to the active state.
Value range:
0 ms
– 3600 ms; step width: 0.1 ms; default: 0 ms.
5
VLS page 1 ...,
navigation item
Return to page 1 of the VLS settings
– DISPLAY24
Table 90
VLS settings page 2
– DISPLAY 24
1
Unit is dependent on the source selected on VLS page 1 Table 89.
VLS settings
page 2
Upper limit
Upper Hysteresis
Act--> inact delay
0
0
0.0 ms
VLS page 1 ...
0.0 ms
Act--> inact delay
VLS settings
page 2
Upper limit
Upper Hysteresis
Act--> inact delay
0
0
0.0 ms
VLS page 1 ...
0.0 ms
Act--> inact delay
1
3
5
2
4