Manual - TC.P Quadro
Control
2016-08-05
88/330
V04.52
3
Window - VLS Settings
3
Input selector,
list box
“None VLS deactivated”
VLS function is switched off
All text boxes are grey, no entries can be made
“Voltage”, “Current”, “Power”
Related text boxes can be edited
The units change depending on the selection made
4
Function selector,
“VLS output is active when voltage” list box
Defines the range in which the relay is activated.
The following options are available:
Exceeds upper limit
– Exceeding a threshold
Falls below lower limit
– Dropping below a threshold
is inside window
– Entering a window
is outside window
– Leaving a window
5
Limits,
text boxes
Related thresholds and hysteresis for the selected range.
Depending on the selection in
-4-
, different text boxes are activated.
6
Relais switching behavior,
text boxes
The adjustable switching delay between the active and the inactive range
helps to ignore brief fluctuations in the output value.
7
Relais switching behavior,
list box
– switching state
Selection of whether the relay is to be closed or opened in the active range.
The switching state is inverted in the non-active range.
8
Relais switching behavior,
list box
– relay type
The following selection is possible:
“OK/Alarm” relay (normally open/normally closed),
“Warn” relay (normally open),
“Run” relay (normally open).
9
<OK>,
button
Closes the VLS window.
Table 51
Window for the VLS function.