Manual - TC.P Quadro
7) Internal (Modulator)
2016-08-05
286/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
8-5
74
Receive register full
Overflow error of receiving com-
munication registers.
Sequence errors due to external
noise coupling.
Find possible noise sources and turning off on a
trial basis.
8-6
75
Modulator comm.
Slow
Communication between modulator
DSP and main DSP too slow
Contact customer support.
Contact customer support.
8-7
76
Undefined ID (Mo-
dulator)
Unknown data packages in the
communication.
Incompatible software versions at
main DSP and modulator
Update the software, following precisely the in-
structions in the manual.
8-7
76
Undefined ID (Mo-
dulator)
Unknown data packages in the
communication.
Sequence errors due to external
noise coupling.
Find possible noise sources and turning off on a
trial basis.
8-8
77
Undefined ID
(Main)
Unknown data packages in the
communication.
Incompatible software versions at
main DSP and modulator
Contact customer support
8-8
77
Undefined ID
(Main)
Unknown data packages in the
communication.
Sequence errors due to external
noise coupling.
Find possible noise sources and turning off on a
trial basis.
8-9
78
VZ gain too low
Internal data overflow caught during
adjustment of the AD converter
gain.
After a software update ensure
that all supplied parameters are
loaded and stored correctly.
Contact customer support
8-10
79
Iprim gain too low
Internal data overflow caught during
adjustment of the AD converter
gain.
After a software update ensure
that all supplied parame-ters are
loaded and stored correctly.
Contact customer support
8-11
7A
Still in fault conditi-
on
You tried to start the modulator
manually, while still being in error
state.
Acknowledge the error and retry
In the case of repeated occurrence: contact cus-
tomer support .
8-12
7B
Fault on reading
scope buffer
Internal error during reading the data
buffer of the modulator.
In the case of repeated occurrence: contact cus-
tomer support.
8-13
7C
Modulator commu-
nication stopped
The modulator does not send any
interrupt sig-nals to the main DSP.
The modulator has been stopped
or is turned off.
Contact customer support
8-14
7D
Wrong Modulator
Version
Modulator version does not match
main DSP software (starting with
firmware of main DSP v4.11.33).
The modulator has not been re-
freshed during software update.
Update the software, following precisely the in-
structions in the manual.
8-14
7D
Wrong Modulator
Version
Modulator version does not match
main DSP software (starting with
firmware of main DSP v4.11.33).
Newest parameters aren’t loaded
after a software update.
Contact customer support