3.3.3.6. Digital outputs (relay contact)
These relay contacts can be used, e.g., for a Versatile Limit Switch
(VLS).
For further information on VLS see chapter 3.3.7, page 84.
As standard the definition of the digital outputs is as follows:
Name
Meaning
X105
Pin no.
Contact type
DIGOUT_1
OK/ALARM
Pin 10, 11
Closed
≙
OK
OK = Device ready for op-
eration
DIGOUT_2
RUN
Pin 12, 13
Closed
≙
Run
RUN = “VOLTAGE_ON”
DIGOUT_3
WARN
Pin 21, 22, 23
Change-over contact
WARN
≙
Warning
Table 46
Standard function of the X105 relay outputs.
Maximum switching current 1 A; maximum switching voltage: 125 V
The rest of the pin definition for X105 is listed in Table 40, page 65.
3.3.4.
Diagnostic and control connection RS-232/DLL/
TopControl application
The diagnostic and control connection can be in the following positions
on the device:
Built-in on the front
Built-in on the rear (option)
If this option is available, it is not possible to use the interface on
the front at the same time.
The RS-232 interface is the main access point for digital control infor-
mation.
Typically
the
connection
is
made
via
a
PC
using
the
TopControl application. The communication between software and the
interface is defined by function calls from a library file (DLL).
The library makes possible:
Complex control and polling functions
Additional device information and function calls in relation to oth-
er interfaces such as the HMI or analogue interface are possible.
Custom programs
You can use your own custom programs to access TopCon
power supplies via the software interfaces in the
function library.
For further information on TopControl see chapter 6.6, page 249.