For Power Supply Models:
600N, 2200N-A, 2200N-B, 12KN-A, 12KN-B, 12KN -C, 12KN-D
POWER SUPPLY
INSTALLATION & ADJUSTMENT
INSTRUCTIONS
Use Exclusively with FLAT
LITE
® Electroluminescent
Lamps.
! IMPORTANT SAFEGUARDS !
When using electrical equipment, basic safety precautions
should always be followed including the following:
• This product must be installed and serviced by electrical
contractors familiar with the instructions in this manual and
local building codes.
• FLAT
LITE
® Lamp is an electrical appliance operating at up to
280Vac.
• Do not cut or pierce without proper tools and training.
• Never power the unit from a dimmable AC source.
• Never for use in or under water.
• Never install in an accessible area without a protective cover to
prevent access.
• Do not install against an ungrounded metal surface.
• Always install in accordance with all applicable electrical
codes.
• Always disconnect power from the FLAT
LITE
® system before
servicing.
• Equipment must be mounted securely in locations and at
heights where it will not be readily subjected to tampering by
unauthorized personnel.
• Use of any components not supplied with the FLAT
LITE
®
system or the modification of the components supplied may
cause an unsafe condition.
• Do not use this equipment for other than its intended purpose
• This equipment is approved and rated for connection of lamps
as specified in the system design section. Never exceed the Total
or Minimum Load Rating of any power supply.
SAVE THESE INSTRUCTIONS
MAKING ADJUSTMENTS
Tools Needed:
•
Phillips head screw driver
•
Nonconductive blade adjustment tool
•
Voltmeter capable of reading up to 400VAC RMS
•
Installed Lamp size (in square inches)
•
Needle-nose pliers
1.
Completely disconnect Power Supply from any power source
2
. If any of the optional CMD modules will be used, leave it
disconnected until the Power Supply has been fully adjusted.
3a
. Models 600N, 2200N-A, B: Remove the cover from the Power
Supply and place the supply base so that the components inside
are accessible and the choke(s) are to the right.
3b.
Models 12KN-A,B,C and D: Remove the access port cover
from the top of the Power Supply and place the supply so that the
opening is toward you and to the right.
4.
Confirm that the input voltage select jumper is placed correctly
for your operating voltage 120 or 240VAC (See Figure 1, 2 or 3 for
jumper location). Refer to the marking on the Printed Circuit
Board (PCB). The jumper tab should connect the front two pins
for 240VAC and the back two pins for 120VAC. (Disregard this
step for Models 12KN-A,B,C,D - voltage adjusts automatically).
5.
Next, match the Power Supply to the lamp size by connecting
the chokes appropriately (see specifics in Figure 1, 2, or 3. Note:
2200N-B requires no choke setup, and chokes on 12KN models
are factory set).
6.
Locate the output “VOLTAGE ADJ” (white pot) and limit-
adjust “VOLTAGE LIMITING” (blue pot) potentiometers. See
Figure 1, 2 or 3 for locations. When adjusting these pots use a
NON CONDUCTIVE TOOL.
7.
The blue limit pot is preset at the factory and is locked with
glue. Set up instructions for this blue limit pot are included in
case the glue has been removed or specific instructions to adjust
the pot are given from the factory. Turn the white pot all the
way counter clockwise and the blue limit pot all the way
clockwise.
E-Lite Technologies, Inc. Power Supply Instruction Manual - Page 1 of 4