P/N 016-5030-020 Rev. D
33
VIPER 4
system, write down the current system settings for future reference. Recalibrate the SmarTrax MD system after
it has been reset.
NOTE:
If Reset SmarTrax is selected, the SmarTrax MD system must be recalibrated before the system can be
enabled. Refer to the Calibrate the SmarTrax MD System section on page 18 for information on
completing the SmarTrax MD system calibration.
DIAGNOSTICS TAB
•
Left and Right Manual Steer
- Used to manually test the SmarTrax MD system. Select one of the numeric
settings (1 being very low, 6 being very high) positioned around the steering wheel graphic or the Min or Max
button to steer the machine. If it does not respond as expected, the PWM values may need to be adjusted.
•
PWM Values
- Displays SmarTrax MD PWM minimum, maximum, and gain values. Adjustment of these values
is not typically necessary. Raven Industries recommends leaving these values as configured by the SmarTrax
MD system unless a technician instructs you to modify the settings.
•
Learning Mode
- Enable the learning mode feature to allow the system to automatically adjust system
response during operation. This feature allows the SmarTrax MD system to adjust the PWM minimum values
during field operation to continuously tune the steering response for monitored field conditions. Disable
learning mode to keep the system from automatically tuning the PWM minimum values and disable automatic
system response adjustment. Raven Industries does not typically recommend enabling learning mode to avoid
unexpected changes to PWM values.
NOTE:
If the PWM values are adjusted, the SmarTrax MD system will no longer automatically adjust the PWM
minimum values unless the Learning Mode function is enabled again.
Edit
SmarTrax MD
System Diagnostic
Содержание SmarTrax MD
Страница 6: ...Table of Contents iv SmarTrax MD Calibration Operation Manual ...
Страница 10: ...CHAPTER 1 4 SmarTrax MD Calibration Operation Manual ...
Страница 14: ...CHAPTER 2 8 SmarTrax MD Calibration Operation Manual ...
Страница 46: ...CHAPTER 3 40 SmarTrax MD Calibration Operation Manual ...
Страница 76: ...CHAPTER 4 70 SmarTrax MD Calibration Operation Manual ...
Страница 112: ...CHAPTER 6 106 SmarTrax MD Calibration Operation Manual ...
Страница 114: ...CHAPTER 7 108 SmarTrax MD Calibration Operation Manual FIGURE 1 Cruizer II with Phoenix 300 and Slingshot Steering Only ...
Страница 115: ...7 P N 016 5030 020 Rev D 109 SYSTEM DIAGRAMS FIGURE 2 Envizio Pro or Viper Pro with Slingshot Steering Only ...
Страница 116: ...CHAPTER 7 110 SmarTrax MD Calibration Operation Manual ...
Страница 131: ...P N 016 5030 020 Rev D 125 ROADWAY HOMOLOGATION CERTIFICATION ...
Страница 132: ...CHAPTER 8 126 SmarTrax MD Calibration Operation Manual ...