MI14-40B / Page 8 / 10
<QF7720955 rev 2>
LOWER ALTERNATOR -
(use new hardware for cable connection)
15.
Jumper cable (positive cable) installation
.
a) Fit jumper cable (a.k.a. positive cable) onto
B1+
stud terminal on lower alternator (figures 7 &
10).
b) Place one new flat washer #5001341 against the jumper cable ring terminal and screw new nut
#5001787 (nut torque: 10 lbf-ft) (figure 10).
16. Fit the ground cable onto the alternator ground stud, place one new flat washer #502573 against the
ground cable ring terminal and screw a new nut #5001182 (nut torque: 6 lbf-ft) (figure 10).
FIGURE 10
17. Plug alternator harness onto lower
alternator connector and secure
using two nylon cable ties #504637
(figure 11).
FIGURE 11