SECTION 06B: ELECTRICAL
36
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A50 J1:11 but
output not active
Transmission
always on
Neutral
•
A50 module failure
•
Connector C717 corroded
•
Circuit 231 shorted to battery
FMI 4
Shorted Low
Output A50 J1:11
shorted to ground
Transmission
Shifting not
working
•
A50 module failure
•
Connector C717 corroded
•
Circuit 231 shorted to ground
MID 188 PSID # 112 Under Floor lights (A47 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A47 J1:20
shorted to ground
Baggage
compartment lights
L176, L177, L180,
L181, L182 or L183
not working
•
A47 module failure
•
Connector C6, C2 or C59
corroded
•
Circuit 10A shorted to ground
FMI 6
Current
above normal
Output A47 J1:20
internal software
fuse active for
overcurrent
Baggage
compartment lights
L176, L177, L180,
L181, L182 or L183
not working
•
A47 module failure
•
Connector C6, C2 or C59
corroded
•
Circuit 10A shorted to ground
MID 188 PSID # 31 Unloader LH (A52 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A52 J1:8 but
output not active
Unloader LH
L200 always
ON
•
A52 module failure
•
Connector C91 or C19 corroded
•
Circuit 33 shorted to battery
FMI 4
Shorted Low
Output A52 J1:8
shorted to ground
Unloader LH
L200 not
working
•
A52 module failure
•
Unloader LH L200 failure
•
Connector C91 or C19 corroded
•
Circuit 33 shorted to ground
FMI 5
Open Circuit
A52 module does not
detect Unloader LH
L200
Unloader LH
L200 not
working
•
A52 module failure
•
Unloader LH L200 failure
•
Circuit 33 open
FMI 6
Current
above normal
Output A52 J1:8
internal software fuse
active for overcurrent
Unloader LH
L200 not
working
•
A52 module failure
•
Connector C91 or C19 corroded
•
Circuit 33 shorted to ground
MID 188 PSID # 32 Unloader RH (A52 J1:21)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A52 J1:21 but
output not active
Unloader RH
L199 always
ON
•
A52 module failure
•
Connector C91 or C19 corroded
•
Circuit 31 shorted to battery
FMI 4
Shorted Low
Output A52 J1:21
shorted to ground
Unloader RH
L199 not
working
•
A52 module failure
•
Unloader RH L199 failure
•
Connector C91 or C19 corroded
•
Circuit 31 shorted to ground
Содержание X3-45 COMMUTER
Страница 4: ......
Страница 20: ......
Страница 50: ......
Страница 82: ......
Страница 198: ......
Страница 202: ......
Страница 212: ......
Страница 232: ......
Страница 270: ......
Страница 304: ......
Страница 322: ......
Страница 351: ...SECTION 16 SUSPENSION DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019 9...
Страница 352: ...SECTION 16 SUSPENSION 10 DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019...
Страница 370: ......
Страница 474: ......
Страница 542: ......