SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
19
fault:
Description:
Symptoms:
FMI 3
Shorted High
Voltage present on
output A48 J1:7 but
output not active
Front Flasher RH
L61 and Marker
L63 always ON
•
A48 module failure
•
Connector C243 corroded
•
Circuit 46 shorted to battery
FMI 4
Shorted Low
Output A48 J1:7
shorted to ground
Front Flasher RH
L61 and Marker
L63 not working
•
A48 module failure
•
Connector C243 corroded
•
Circuit 46 shorted to ground
FMI 5
Open Circuit
A48 module does not
detect Front Flasher
LH L62
Front Flasher RH
L61 and Marker
L63 not working
•
A48 module failure
•
Front Flasher RH L61 and
Marker L63 open circuit
•
Circuit 46 open
FMI 6
Current
above normal
Output A48 J1:7
internal software fuse
active for overcurrent
Front Flasher RH
L61 and Marker
L63 not working
•
A48 module failure
•
Connector C243 corroded
•
Circuit 46 shorted to ground
MID 188 PSID # 56 FrStart Enable Sw (A53 J1:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A53 J1:9 but
switch Sw58 not
active
Engine cannot
be started or
stopped from
rear
•
A53 module failure
•
Rear start switch Sw58 failure
•
Connector C91 corroded
•
Circuit 85C shorted to battery
FMI 4
Shorted Low
Output A53 J1:9
shorted to ground
Engine cannot
be started from
front
•
A53 module failure
•
Rear start switch Sw58 failure
•
Connector C91 corroded
•
Circuit 85C shorted to ground
MID 188 PSID # 81 Fuel Filt Sens (A49 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A49 J1:20
No warning of
water in fuel
filter on dash
•
A49 module failure
•
Connector C91 corroded
•
Connector C78 corroded
•
Circuit 197 shorted to battery
FMI 4
Shorted Low
Input A49 J1:20
shorted to ground
Fuel water filter
sensor always
On on dash
•
A49 module failure
•
Fuel water filter Se12 failure
•
Connector C91 corroded
•
Connector C78 corroded
•
Circuit 197 shorted to ground
MID 188 PSID # 138 Hazard Switch (A36 JB:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A36 JB:4 but
switch Sw4 not active
Hazard lights
always ON
•
A36 module failure
•
Hazard switch Sw4 failure
•
Connector C71 corroded
•
Circuit 22 shorted to battery
Содержание X3-45 COMMUTER
Страница 4: ......
Страница 20: ......
Страница 50: ......
Страница 82: ......
Страница 198: ......
Страница 202: ......
Страница 212: ......
Страница 232: ......
Страница 270: ......
Страница 304: ......
Страница 322: ......
Страница 351: ...SECTION 16 SUSPENSION DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019 9...
Страница 352: ...SECTION 16 SUSPENSION 10 DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019...
Страница 370: ......
Страница 474: ......
Страница 542: ......