SECTION 06B: ELECTRICAL
34
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
not active
•
Circuit 79 shorted to battery
FMI 4
Shorted Low
Output A51 J1:1
shorted to ground
Cruise control not
working, transmission
sees service brake
signal ON all the time
•
A51 module failure
•
Connector C717 corroded
•
Circuit 79 shorted to ground
FMI 6
Current
above normal
Output A51 J1:1
internal software
fuse active for
overcurrent
Cruise control not
working
•
A51 module failure
•
Connector C717 corroded
•
Circuit 79 shorted to ground
MID 188 PSID # 60 Starter Relay (A53 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A53 J1:6
shorted to ground
Rear Starter
not working
•
Vehicle ECU failure
•
A53 module failure
•
Rear Starter Relay failure
•
Connector C397 corroded
•
Circuit 231A shorted to ground
FMI 6
Current
above normal
Output A53 J1:6
internal software fuse
active for overcurrent
Rear Starter
not working
•
A53 module failure
•
Connector C397 corroded
•
Circuit 231A shorted to ground
MID 188 SID # 77 Step Led light (A43 J1:30)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present
on output A43
J1:30 but output
not active
Step Nozzle Light
L20A always ON
•
A43 module failure
•
Connector C6 or C65 corroded
•
Circuit 35A shorted to battery
FMI 4
Shorted Low
Output A43 J1:30
shorted to ground
Step Nozzle Light
L20A not working
•
A43 module failure
•
Connector C6 or C65 corroded
•
Circuit 35A shorted to ground
FMI 6
Current
above normal
Output A43 J1:30
internal software
fuse active for
overcurrent
Step Nozzle Light
L20A not working
•
A43 module failure
•
Connector C6 or C65 corroded
•
Circuit 35A shorted to ground
MID 188 PSID # 117 StepLts (A47 J1:5)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A47 J1:5 but
output not active
Step Lights L18,
L19 or L20
always ON
•
A47 module failure
•
Connector C63 corroded
•
Circuit 35 shorted to battery
FMI 4
Shorted Low
Output A47 J1:5
shorted to ground
Step Lights L18,
L19 or L20 not
working
•
A47 module failure
•
Connector C63 corroded
•
Circuit 35 shorted to ground
FMI 5
Open Circuit
A47 module does not
detect Step Lights
L18, L19 or L20
Step Lights L18,
L19 or L20 not
working
•
A47 module failure
•
Circuit 35 open
FMI 6
Current
above normal
Output A47 J1:5
internal software fuse
active for overcurrent
Step Lights L18,
L19 or L20 not
working
•
A47 module failure
•
Connector C63 corroded
•
Circuit 35 shorted to ground
Содержание X3-45 COMMUTER
Страница 4: ......
Страница 20: ......
Страница 50: ......
Страница 82: ......
Страница 198: ......
Страница 202: ......
Страница 212: ......
Страница 232: ......
Страница 270: ......
Страница 304: ......
Страница 322: ......
Страница 351: ...SECTION 16 SUSPENSION DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019 9...
Страница 352: ...SECTION 16 SUSPENSION 10 DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019...
Страница 370: ......
Страница 474: ......
Страница 542: ......