SECTION 06B: ELECTRICAL
14
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
MID 188 PSID # 65 Ent Close Sol (A47 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A47 J1:6 but
output not active
Close Solenoid
Valve So6
always ON -
Entrance door
cannot be
opened
•
A47 module failure
•
Close solenoid valve So6
failure
•
Circuit 49A shorted to battery
FMI 4
Shorted Low
Output A47 J1:6
shorted to ground
Entrance door
cannot be
closed with
switch
•
A47 module failure
•
Close solenoid valve So6
failure
•
Circuit 49A shorted to ground
FMI 5
Open Circuit
A47 module does not
detect Close
Solenoid Valve So6
Entrance door
cannot be
closed with
switch
•
A47 module failure
•
Close solenoid valve So6 open
•
Circuit 49A open
FMI 6
Current
above normal
Output A47 J1:6
internal software fuse
active for overcurrent
Entrance door
cannot be
closed with
switch
•
A47 module failure
•
Circuit 49A shorted to ground
•
Close solenoid valve So6
shorted to ground
MID 188 PSID # 64 Ent Door Close (A36 JB:10)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage above
normal on A36 J1:10
Entrance door
cannot be closed
with switch
•
A36 module failure
•
Connector C71 corroded
•
Circuit 49A shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A36 JB:10
Entrance door
cannot be
opened
•
A36 module failure
•
Inside switch close Sw32
failure
•
Connector C71 corroded
•
Circuit 49A shorted to
ground
MID 188 PSID # 71 Ent open out (A36 JB:15)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage above
normal on A36 J1:15
Entrance door
cannot be
closed
•
A36 module failure
•
Sw34 failure
•
Connector C6 corroded
•
Circuit 47 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A36 JB:15
Entrance door
cannot be
opened with
switch
•
A36 module failure
•
Sw34 failure
•
Connector C6 corroded
•
Circuit 47 shorted to ground
MID 188 PSID # 67 Ent Open Sol (A47 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
Содержание X3-45 COMMUTER
Страница 4: ......
Страница 20: ......
Страница 50: ......
Страница 82: ......
Страница 198: ......
Страница 202: ......
Страница 212: ......
Страница 232: ......
Страница 270: ......
Страница 304: ......
Страница 322: ......
Страница 351: ...SECTION 16 SUSPENSION DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019 9...
Страница 352: ...SECTION 16 SUSPENSION 10 DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019...
Страница 370: ......
Страница 474: ......
Страница 542: ......