SECTION 06B: ELECTRICAL
6
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
MID 188 PSID # 41 Cond Rly spd1 (A54 J1:5)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A54 J1:5 but
output not active
Condenser
fans always ON
speed 1
•
A54 module failure
•
Cond Power Relay R10 failure
•
Circuit 67A shorted to battery
FMI 4
Shorted Low
Output A54 J1:5
shorted to ground
Condenser
fans not
working
•
A54 module failure
•
Cond Power Relay R10 failure
•
Circuit 67A shorted to ground
FMI 5
Open Circuit
A54 module does not
detect power relay
R10
Condenser
fans not
working
•
A54 module failure
•
Cond Power Relay R10 failure
•
Power Relay R10 open circuit
•
Circuit 67A open
FMI 6
Current
above normal
Output A54 J1:5
internal software fuse
active for overcurrent
Condenser
fans not
working
•
A54 module failure
•
Circuit 67A shorted to ground
MID 188 PSID # 42 Cond Rly spd2 (A49 J1:16)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A49 J1:16 but
output not active
Condenser
fans not
working on
speed 2
•
A49 module failure
•
Connector C21 corroded
•
Connector C58 corroded
•
Circuit 2B shorted to battery
FMI 4
Shorted Low
Output A49 J1:16
shorted to ground
Condenser
fans always ON
speed 2
•
A49 module failure
•
Connector C21 corroded
•
Connector C58 corroded
•
Circuit 2B shorted to ground
FMI 6
Current
above normal
Output A49 J1:16
internal software fuse
active for overcurrent
Condenser
fans always ON
speed 2
•
A49 module failure
•
Condenser motors failure
•
Connector C21 corroded
•
Connector C58 corroded
•
Circuit 2B shorted to ground
MID 188 PSID # 116 Cyclope Lt (A51 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A51 J1:7 but
output not active
Center High
mounted stop
light L81
always ON
•
A51 module failure
•
Connector C12 corroded
•
Connector C91 corroded
•
Circuit 82A shorted to battery
FMI 4
Shorted Low
Output A51 J1:7
shorted to ground
Center High
mounted stop
light L81 not
working
•
A51 module failure
•
Connector C12 corroded
•
Connector C91 corroded
•
Circuit 82A shorted to ground
FMI 6
Current
above normal
Output A51 J1:7
internal software fuse
active for overcurrent
Center High
mounted stop
light L81 not
working
•
A51 module failure
•
Connector C12 corroded
•
Connector C91 corroded
•
Circuit 82A shorted to ground
•
Low resistance value
Содержание X3-45 COMMUTER
Страница 4: ......
Страница 20: ......
Страница 50: ......
Страница 82: ......
Страница 198: ......
Страница 202: ......
Страница 212: ......
Страница 232: ......
Страница 270: ......
Страница 304: ......
Страница 322: ......
Страница 351: ...SECTION 16 SUSPENSION DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019 9...
Страница 352: ...SECTION 16 SUSPENSION 10 DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019...
Страница 370: ......
Страница 474: ......
Страница 542: ......