SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
25
working
•
Circuit 58R shorted to ground
MID 188 PSID # 153 Lower Stop Lamps (A50 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A50 J1:6 but
output not active
Lower stop
lamps always
ON
•
A50 module failure
•
Circuit 82Low shorted to
battery
FMI 4
Shorted Low
Output A50 J1:6
shorted to ground
Lower stop
lamps not
working
•
A50 module failure
•
Circuit 82Low shorted to
ground
FMI 6
Current
above normal
Output A50 J1:6
internal software fuse
active for overcurrent
Lower stop
lamps not
working
•
A50 module failure
•
Circuit 82Low shorted to
ground
MID 188 PSID # 181 Lower Washer pmp (A46 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A46 J1:3
shorted to ground
Windshield
washer pumps
Mo19 and Mo20
not working
•
A46 module failure
•
Windshield washer pump
Mo19 or Mo20 failure
•
Connector C4 corroded
•
Connector C61 corroded
•
Circuit 53F shorted to ground
FMI 5
Open Circuit
A46 module does not
detect Windshield
washer pumps Mo19
and Mo20
Windshield
washer pumps
Mo19 and Mo20
not working
•
A46 module failure
•
Windshield washer pump
Mo19 or Mo20 open circuit
•
Circuit 53F open
FMI 6
Current
above normal
Output A46 J1:3
internal software fuse
active for overcurrent
Windshield
washer pumps
Mo19 and Mo20
not working
•
A46 module failure
•
Connector C4 corroded
•
Connector C61 corroded
•
Circuit 53F shorted to ground
MID 188 SID # 71 Master Interlock Sw (A36 JB:16)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A36 JB:16 but
switch Sw140 not
active
Master
Interlock
Bypass not
working
•
A36 module failure
•
Circuit Master shorted to battery
FMI 4
Shorted Low
Input A36 JB:16
shorted to ground
Master
Interlock
Bypass
always ON
•
A36 module failure
•
Master Interlock Bypass switch
Sw140 failure
•
Circuit Master shorted to ground
Содержание X3-45 COMMUTER
Страница 4: ......
Страница 20: ......
Страница 50: ......
Страница 82: ......
Страница 198: ......
Страница 202: ......
Страница 212: ......
Страница 232: ......
Страница 270: ......
Страница 304: ......
Страница 322: ......
Страница 351: ...SECTION 16 SUSPENSION DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019 9...
Страница 352: ...SECTION 16 SUSPENSION 10 DOB 2490 2789 X3 45 Commuter PA1605 Maintenance Manual Section 16 revised April 2019...
Страница 370: ......
Страница 474: ......
Страница 542: ......