POWER ELECTRONICS
SD300
DESCRIPTION OF PROGRAMMING PARAMETERS
125
Screen Description Default
value
Range
Function
Set
on
RUN
bA.48
User Voltage
4
0%
0 to 100%
Set user voltage 4. The drive will provide the
frequency set in parameter when the
frequency configured in bA.47 is reached.
NO
St1
[1]
Multi-
Reference1
1000%
0.00 to dr.20
The user can set multiple speed references
for the drive. This will be enabled by the use
of the digital inputs configured as speed multi-
references.
The speed applied in each situation will
depend on the digital inputs that control the
multi-references, which are set as SPEED-L,
SPEED-M and SPEED-H.
For example, with the following options:
-
In.65 ED1 =
‘
Speed-
H′
-
In.65 ED2 =
‘
Speed -
M′
-
In.65 ED3 =
‘
Speed-
L′
The adjustment is carried out by assigning a
speed value for every parameter within this
group, from St1-St3 and bA53-bA.56.
The following table links the digital inputs
configured as SPEED to the selected multi-
reference:
YES
St2
[1]
Multi-
Reference2
2000 %
YES
St3
[1]
Multi-
Reference3
3000%
YES
bA.53
[5]
Multi-
Reference4
4000%
YES
bA.54
Multi-
Reference5
5000%
YES
bA.55
Multi-
Reference6
6000%
YES
[1] Displayed when an LCD keypad is in use.
[5] These parameters will only be displayed if one of In.65-ln71 is set to SPEED-L/M/H.
Содержание SD 300 Series
Страница 1: ...SD300 GETTING STARTED MANUAL LOW VOLTAGE VARIABLE SPEED DRIVE ...
Страница 2: ......
Страница 3: ...Variable Speed Drive Getting Started Manual Edition February 2019 SD30IM01GI Rev G ...
Страница 159: ...POWER ELECTRONICS SD300 DESCRIPTION OF PROGRAMMING PARAMETERS 157 Power off delay ...
Страница 174: ...SD300 POWER ELECTRONICS 172 DESCRIPTION OF PROGRAMMING PARAMETERS TI configuration ...
Страница 352: ......
Страница 353: ......
Страница 354: ...24H TECHNICAL ASSISTANCE 365 DAYS A YEAR FIND YOUR NEAREST DELEGATION POWER ELECTRONICS COM CONTACT ...