DESCRIPTION OF PROGRAMMING PARAMETERS
Screen Description Default
value
Range
Function
Set
on
RUN
dr.93
Parameter
initialization
No
No
All
dr
bA
Ad
Cn
In
OU
CM
AP
Pr
M2
run
Set parameters back to their factory value.
OPT. DESCR. FUNCTION
0
No
All parameters keep their
current value.
1
All
Initializes all parameter
groups (set to factory
values).
2
dr
Initialize group dr.
3
bA
Initialize group bA.
4
Ad
Initialize group Ad.
5
Cn
Initialize group Cn.
6
In
Initialize group In.
7
OU
Initialize group OU.
8
CM
Initialize group CM.
9
AP
Initialize group AP.
12
Pr
Initialize group Pr.
13
M2
Initialize group M2.
16
run
Initialize group Operation.
NO
dr.94
Password
register
0
0 to
9999
Password for ‘dr.95
➔
Parameters lock’. It is
set as Hexadecimal value.
Note:
To register a password for the first time:
1. In
‘dr.94’, press ‘Ent’ key twice.
2. Register the password (except ‘0’) and press
‘Ent’ key (the value will blink).
3. Press ‘Ent’ key again to save the value and
return to ‘dr.94’.
Note
:
To change the password, follow the next steps:
1. In ‘dr.94’, press ‘Ent’ key once.
2. Introduce the present password and press
‘Ent’ key again.
3. Introduce the new password and press ‘Ent’
key (the value will blink).
4. Press ‘Ent’ key again to save the value and
return to ‘dr.94’.
YES
Содержание SD 300 Series
Страница 1: ...SD300 GETTING STARTED MANUAL LOW VOLTAGE VARIABLE SPEED DRIVE ...
Страница 2: ......
Страница 3: ...Variable Speed Drive Getting Started Manual Edition February 2019 SD30IM01GI Rev G ...
Страница 159: ...POWER ELECTRONICS SD300 DESCRIPTION OF PROGRAMMING PARAMETERS 157 Power off delay ...
Страница 174: ...SD300 POWER ELECTRONICS 172 DESCRIPTION OF PROGRAMMING PARAMETERS TI configuration ...
Страница 352: ......
Страница 353: ......
Страница 354: ...24H TECHNICAL ASSISTANCE 365 DAYS A YEAR FIND YOUR NEAREST DELEGATION POWER ELECTRONICS COM CONTACT ...