RealPresence Collaboration Server (RMX) 800s/Virtual Edition Administrator’s Guide
Polycom®, Inc.
722
The
System Flags
dialog box opens.
2
Modify the values of the following flags:
Flag Values for Accessing External Database Application
3
Click
OK
.
4
Reset the MCU for flag changes to take effect.
Enabling External Database Validation for Starting New Ongoing Conferences
The validation of the participant’s right to start a new conference with an external database application is
configured in the
Entry Queue IVR Service - Global
dialog box.
Flag
Description and Value
ENABLE_EXTERNAL_DB_ACCESS
The flag that enables the use of the external database application.
EXTERNAL_DB_IP
The IP address of the external database application server. default
IP: 0.0.0.0.
EXTERNAL_DB_PORT
The port number used by the MCU to access the external
application server.
Default Port = 80.
EXTERNAL_DB_LOGIN
The user name defined in the external database application for the
MCU.
EXTERNAL_DB_PASSWORD
The password associated with the user name defined for the MCU
in the external database application.
EXTERNAL_DB_DIRECTORY
The URL of the external database application.