Workshop Manual, TPD 1350, issue 3
265
23
New 1000 Series
If the warning light is not illuminated when the
switch is in the "on" position:
Check the bulb. If no fault:
Check all the connections at the regulator, at the
alternator and at the battery.
If no fault:
Turn the switch to the "off" position. Disconnect the
wire from the "F" terminal on the alternator and
connect a wire between the "F" terminal and the
negative terminal on the alternator. Turn the switch to
the "on" position.
If the warning light shows, the fault is in the regulator.
If the warning light does not show, the fault is in the
alternator.
If the warning light continues to show and the
ammeter shows no output when the alternator is
in operation:
Check all the connections at the regulator, alternator
and battery.
If no fault:
Turn the switch to the "off" position. Disconnect the
wire from the "F" terminal on the alternator and
connect a wire between the "F" terminal and the
negative terminal on the alternator. Turn the switch to
the "on" position and operate the engine at fast idle.
If there is no output, there is a fault in the alternator.
If there is an output, there is a fault in the regulator.
If the warning light continues to show when the
alternator is in operation and the ammeter shows
a reduced output with maximum output only at
maximum engine speed or,if the warning light
does not show, but there is a reduced output from
the alternator with maximum output only at
maximum engine speed:
There is a fault in the alternator.
If there is an intermittent light from the warning
light and the ammeter needle is not stationary
when the battery is charged fully and no load is
applied:
Check for a higher than normal resistance in the
negative control wire of the regulator.
If the resistance is normal, there is a fault in the
regulator.
If the battery charge is too high and the ammeter
indicates high or maximum output at all times:
Check the positive control wire and its connection at
the regulator.
If the wire and its connection are correct, there is a
fault in the regulator.
Purchased from www.WorkshopManuals.co.uk
Содержание New 1000 Series
Страница 16: ...10 16 Workshop Manual TPD 1350 issue 3 New 1000 Series L A0378N A0379...
Страница 30: ...30 This page is intentionally blank...
Страница 62: ...62 This page is intentionally blank...
Страница 108: ...108 This page is intentionally blank...
Страница 140: ...140 This page is intentionally blank...
Страница 160: ...19 160 Workshop Manual TPD 1350 issue 3 New 1000 Series 1 2 3 4 A A0289...
Страница 161: ...Workshop Manual TPD 1350 issue 3 161 19 New 1000 Series A A0290 1 2 3...
Страница 180: ...180 This page is intentionally blank...
Страница 284: ...284 This page is intentionally blank...