![Perimeter Technology VU-ACD /100 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/perimeter-technology/vu-acd-100/vu-acd-100_maintenance-manual_1529976064.webp)
2-46
Maintenance Utilities
VU-ACD™/100 Maintenance Guide – Host/DOS
2.6.2
Maintenance Modem Configuration
Step
Prompt
Action
1
SYSTEM HARDWARE CONFIGURATION
1) Node Configuration
2) Maintenance Modem Configuration
3) Tape Configuration
4) Multiport Serial I/O Configuration
5) System Printer Configuration
6) Reset All External Displays
Select an option or ‘q’ to quit:
Type
2
and press
Enter
to select Maintenance
Modem Configuration.
2
VIEW/MODIFY MAINTENANCE MODEM CONFIGURATION
1) Port
/dev/ttyi1B
2) Baud Rate
9600
3) Modem selection
Generic Modem
4) Initialize the modem
Select an option or ‘q’ to quit
Type the number corresponding to the remote
maintenance modem configuration parameter
you wish to change and press
Enter
. Steps 3, 4
and 5 describe how to change the port, baud
rate and initialize the modem parameters
respectively.
3A
1) Port
/dev/tty1B
Type
1
and press
Enter
to modify the serial
port assignment for the remote maintenance
modem.
3B
MAINTENANCE MODEM PORT ASSIGNMENT
List of configured serial tty devices
Note: although configured, devices may not
be available to use. Ensure that a serial device
is available prior to assigning it.
ttyi1B
ttyi2B
ttyi2g
ttyi2H
Enter the serial port for the MODEM or
‘q’ to quit [ ]
Type the serial port number to be assigned to
the modem and press
Enter
. The View/Modify
Maintenance Modem Configuration screen
reappears.
Choose another modem configuration
parameter to change or proceed to Step 6.
4A
2) Baud Rate
9600
Type
2
and press
Enter
to modify the baud rate
for the remote maintenance modem.
4B
Baud rates supported are:
1) 1200
2) 2400
3) 4800
4) 9600
5) 19200
6) 38400
Select the baud rate: [ ]
Type the number corresponding to the baud
rate of the remote maintenance modem and
press
Enter
. The View/Modify Maintenance
Modem Configuration screen reappears.