4-23
VU-ACD™/100 Maintenance Guide – Host/DOS
Troubleshooting
4.2.5
Verifying ACD MIS Datafill
1
To ensure that the switch software is at BCS32 or greater type
PATCHER;INFORM
LIST;LEAVE
and press
Enter
. Look for BCS32 or greater software.
2
To ensure that the correct software packages are loaded type
PATCHER;INFORM
LIST;LEAVE
and press
Enter
. The MAP displays a list of feature packages. For ACD
MIS operation the following software packages should be in the displayed list:
•
NTX000AA
Bilge
•
NTX001AA
Common Basic
•
NTX100AA
Meridian Digital Centrex - Basic
•
NTX106AA
Business Set Features
•
NTX108AA
Business Set Display Features
•
NTX407AB
ACD Call Processing Control
•
NTX415AA
ACD Basic
•
NTX416AB
ACD Enhanced II
•
NTX273AA
Multi-protocol Controller
•
NTX560AA
NOP Generic Remote Operation Service
•
NTX991AA
ACD Management Reports Two-Way Data Stream
3
The following tables must be datafilled according to the engineering specifications for
the office:
•
Table
MPC
•
Table
MPCLINK
•
Table
GDLADEV
•
Table
NOPADDR
•
Table
ACDMISSP
•
Table
ACDMISPL
•
Table
ACDFRP
•
Table
ACDSGRP
4
Verify that the parameters used by the ACD MIS data link are correctly entered in Tables
OFCENG
and
OFCOPT
.
5
Activate the ACD MIS data link. A change in the
NOS_QUANTITY_OF_SVCS
or
MAX_ACDMIS_SESSIONS
office parameter requires a warm restart of the DMS-100. If
no restart is required, the ACD MIS data link will be activated when the datafill is
complete.
6
With an MPC card installed type
MAPCI;MTC;IOD;IOC
n
, where
n
is the index of the
IOC. Look for an MPC card in the appropriate IOC card slot.
IOC CARD 0 1 2 3 4 5 6 7 8
3 PORT 0123 0123 0123 0123 0123 0123 0123 0123 0123
STAT .- - - P- - - .- - - .- - - - - - - - - - - .- - - .- - - .- - -
TYPE DLC MPC DLC DLC MTD MTD MPC DLC MPC
NOTE: If remote load management is used, then NTXA52AA, Remote Load Management should
also appear in the list.