- 67 -
Closely related.
P1-03
Motor 1
rated
current
Model
determined
0.01A
~
655.35A
( AC motor frequency≤
55kW)
P1-04
Motor 1
rated
frequency
Model
determined
0.01Hz
~
max
frequency
P1-05
Motor 1
rated rmp
Model
determined
1rpm
~
65535rpm
P1-06
Asynchron
ous motor
1 stator
power
Resistance
Model
determined
0.001Ω
~
65.535Ω
( AC motor frequency≤
55kW)
P1-06 ~ P1-10 is the parameters
of the induction motor, can be
obtained through the motor self-
learning. Among them, the
asynchronous part of the
asynchronous parameters of self-
learning can only get P1-06 ~ P1-
08 three parameters,
asynchronous machine dynamic
complete learning can get P1-06 ~
P1-10, you can also get the
encoder phase sequence P1-30. If
the scene is not on the motor self-
learning, according to the motor
manufacturers to provide the
parameters, enter the
corresponding function code.
P1-07
Asynchron
ous motor
1 rotor
electric
Resistance
Model
determined
0.001Ω
~
65.535Ω
( AC motor frequency≤
55kW)
P1-08
Asynchron
ous motor
1 leakage
inductance
Model
determined
0.01mH
~
655.35mH
( AC motor frequency≤
55kW)
P1-09
Asynchron
ous motor
1 mutual
inductance
Model
determined
0.1mH
~
6553.5mH
( AC motor frequency≤
55kW)
P1-10
Asynchron
ous motor
1
No-load
current
Model
determined
0.01A
~
P1-03
( AC motor frequency≤
55kW)
P1-27
Number of
encoder
lines
1024
1
~
65535
Set the number of pulses per
revolution of the encoder. In the
speed sensor vector control mode
(FVC), the number of encoder
pulses must be set correctly,
otherwise the motor will not run
normally.