- 40 -
P5-22
active mode selection
0: Positive logic
1: anti logic
Bit: HDO (HDY)
Ten: RO1A
Hundred places: RO2A
Thousands of bits: DO
Million: reserved
00000
☆
Function
Code
Name
Set Range
default
Alteration
P6 Start/Stop Control
P6-00
Start mode
0: Direct start
1: Catching a spinning motor
2: Pre-excited start
3: SVC quick start
0
☆
P6-01
Mode of catching a spinning
motor
0: From stop frequency
1: From 50 Hz
2: From max. frequency
0
★
P6-02
Speed of catching a spinning
motor
1
~
100
20
☆
P6-03
Start frequency
0.00Hz
~
10.00Hz
0.00Hz
☆
P6-04
Start frequency holding time
0.0s
~
100.0s
0.0s
★
P6-05
DC injection braking 1
level/Pre
excitation level
0%
~
100%
50%
★
P6-06
DC injection braking 1 active
time
/Pre-excitation active time
0.0s
~
100.0s
0.0s
★
P6-07
Acceleration/Deceleration
mode
0:Linear acceleration /
deceleration
1:S-curve acceleration /
deceleration A (static)
2:S curve acceleration /
deceleration B (dynamic)
0
★
P6-08
Time proportion of S-curve
start
segment
0.0%
~(
100.0%-P6-09
)
30.0%
★
P6-09
Time proportion of S-curve
end
segment
0.0%
~(
100.0%-P6-08
)