- 28 -
P0-05
Auxiliary frequency source B
Reference object selection
0: relative to maximum
frequency
1: Relative to frequency source
A
0
☆
P0-06
Auxiliary frequency source B
command range
0%
~
150%
100%
☆
Functi
on
Code
Name
Set Range
default
Alteration
P0-07
Frequency
source
combination mode selection
Bit: frequency source selection
0: Main frequency source A
1: main and auxiliary operation
results (operation relationship
determined by ten)
2: Main frequency source A and
auxiliary frequency source B
switch
3: Main frequency source A and
master and slave operation
result switching
4: auxiliary frequency source B
and master and slave
operation result switching
Ten: frequency source main and
auxiliary operation
relationship
0: main + auxiliary
1: main - auxiliary
2: the two maximum
3: the two minimum
00
☆
P0-08
Preset frequency
0.00Hz
~
max frequency
(
P0-
10
)
50.00Hz
☆
P0-09
Running direction
0
:
same direction 1
:
opposite direction
0
☆
P0-10
Max. frequency
50.00Hz
~
500.00Hz
50.00Hz
★
P0-11
Setting channel of frequency
upper limit
0: P0-12 is set
1: AI1 (Note: J6 jumper)
2: AI2
3: AI3
4: High-speed pulse setting (S5)
5: communication given
0
★
P0-12
Frequency reference upper
limit
Upper limit P0-14
~
max
frequency P0-10
50.00Hz
☆
P0-13
Frequency reference upper
limit offset
0.00Hz
~
max frequency P0-10
0.00Hz
☆