- 88 -
Used to set the delay time for the inverter to change when the S-terminal status changes.
Currently only S1, S2, S3 with the delay time to set the function.
P4-38
S1~S5 Terminal valid
mode selection 1
Factory
value
00000
Set range
Bit
S1 Terminal valid status setting
0
:
Active high 1
:
active low
Ten
S2 Terminal valid status setting
(
0
~
1
,
see
above
)
Hundred
S3 Terminal valid status setting
(
0
~
1
,
see
above
)
Thousand
S4 Terminal valid status setting
(
0
~
1
,
see
above
)
Million
S5 Terminal valid status setting
(
0
~
1
,
see
above
)
Used to set the active status mode of the digital input terminal.
When the selection is active high, the corresponding S terminal is valid when connected to
the GND, and the switch is invalid.
When the selection is active low, the corresponding S terminal is inactive with GND and is
disabled.
P5 Group Output terminal
EV510 series inverter comes standard with two multi-function analog output terminals,
one multi-function digital output terminal, two multi-function relay output terminals,
one HDO terminal (can be selected as high-speed pulse output terminal, Open-circuit
switch output)
P5-00
HDO Terminal output mode
selection
Factory default
0
Set range
0
:
Pulse output
(
HDP
)
1
:
Switch output
(
HDY
)
The HDO terminal is a programmable multiplex terminal that can be used as a high-speed
pulse output terminal or as a switch output terminal with open collector.
When the pulse is output, the maximum frequency of the output pulse is 100 kHz. Refer
to P5-06 for the related function.
P5-01
HDY Output function selection
(
Open
collector output terminal
)
Factory
default
0
P5-02
relay1 Output function selection
(
RO1A-
RO1B-RO1C
)
Factory
default
2
The function of the multi-function output terminal is described below
:
Set
value
Function
description
0
Non-output
The output terminal has no function
1
The inverter is running
Indicates that the inverter is running and has an
output frequency (which may be zero). At this time,
the ON signal is output.
2
Error output(error
When the inverter fails and the fault is stopped, the
ON signal is output.