8
Item
Specification
Timing control
timing control function: setting time range: 0.0min~6500.0min
Multi-motor
switch
2sets of motor parameter, can realize 2motors switching
control
Multi-threading
bus support
Multi threading
bus support
Multi threading
bus support
Support multiple fieldbus: Modbus, RS85, CAN open, CAN
link
Multi-encoder
support
Support differential, open collector, rotary transformer
Command source
control panel, control terminal, communication; can be
switched by several modes
Frequency source
10 types of frequency sources: digital setting, analog voltage
setting, analog current setting, pulse setting,
communication setting, can be switched by several methods
Auxiliary
frequency sources
10 types of auxiliary frequency source, can realize auxiliary
frequency trimming, frequency combining flexibility
Running
Input terminal
Standard:
7 digital input terminal, one of them support max 100KHz HS
pulse input;3 analog input terminal,
one of them support 0~10V voltage input,
one support 0~10V voltage or 0/4~20mA current input,
One support -10~+10V voltage.
Output terminal
Standard:
1 high-speed pulse output terminal(optional open
collector),support 0~100kHzpulse
1 digit output terminals
;
2 relay output terminal
2 analog output terminals, one of them support 0~20mA current
output;
Display and
keypad
LED display
Can display parameter
Press-key locking
and function
selection
Realize press-key partial or full locking, define part press-key
function range, to avoid wrong operation
Protection function
Power-on motor short circuit test, output phase-loss
protection, over-current protection, over-voltage protection,
under-voltage protection, overheat protection, overload
protection etc.