6. Parameter Description
Function
code
Description
Application
P0-01
:
1st motor
speed
control
mode
Set 0
:
non-speed
Sensor vector control
(
SVC
)
Refers to open loop vector control, suitable for
the usual high-performance control occasions, a
drive can only drive a motor. Such as machine
tools, centrifuges, drawing machines, injection
molding machines and other loads.
Set 1
:
with speed
Sensor vector control
(
FVC
)
Refers to the closed-loop vector control, the
motor must be installed encoder, the inverter
must be the same type of adapter with the PG
card. Suitable for high-precision speed control or
torque control of the occasion. A drive can only
drive one motor. Such as high-speed paper
making machinery, lifting machinery, elevators
and other loads.
Set 2
:
V/F control
(
speed degree open
loop control
)
(
Factory default
)
Applicable to the load requirements are not high,
or a drive drag multiple motor occasions, such as
fans, pump load. Can be used for a drive drag
more than one motor occasions.
P0-03
Main frequency
source A selection
Factory default
2
Set range
0: digital setting (preset frequency P0-08, UP / DOWN
can be modified, power is not memory)
1: digital setting (preset frequency P0-08, UP / DOWN
can be modified, power-down memory)
2: AI1 (J6 jumper) 3: AI2 4: AI3
5: High-speed pulse setting (S5)
6: Multi-step command
7: PLC 8: PID 9: Communication
dO-32
Viewing any register address value
0.01Hz
701FH
dO-34
Motor temperature
1
7020H
dO-35
Target torque
1
℃
7022H
dO-36
Resolver position
0.1%
7023H