- 39 -
34: zero current state
35: Module temperature arrives
36: Output current is exceeded
37: Lower frequency arrival
(shutdown also output)
38: Alarm output (continued)
39:Motor over temperature
warning
40: This run time arrives
41: fault output (for free stop
fault), and under voltage is
not output
Function
Code
Name
Set Range
default
Alteration
P5-06
HDP function selection
0: operating frequency
1: Set frequency
2: Output current
3: Output torque
4: Output power
5: Output voltage
6: High speed pulse input
(100.% corresponds to 100.0
kHz)
7: AI1 (Note: J6 jumper)
8: AI2
9: AI3
10: length
11: count value
12: communication settings
13: motor speed
14: Output current: 100.0% vs.
1000.0A
15:Output voltage: 100.0%
corresponds to 1000.0V
16: motor output torque (actual
value, relative motor
percentage)
0
☆
P5-07
AO1 function selection
0
☆
1
☆
P5-09
HDO output frequency
0.01kHz
~
100.00kHz
50.00kHz
☆
P5-10
AO1 zero offset coefficient
-100.0%
~
+100.0%
0.0%
☆
P5-11
AO1 gain
-10.00
~
+10.00
1.00
☆
P5-17
HDY output delay
0.0s
~
3600.0s
0.0s
☆
P5-18
Relay 1 output delay
0.0s
~
3600.0s
0.0s
☆
P5-20
DO output delay
0.0s
~
3600.0s
0.0s
☆