- 33 -
P2-21
Max. torque coefficient of
field
weakening area
50~200%
100%
☆
P2-22
Regenerative power limit
selection
0: Disabled
1: Enabled
0
☆
P2-23
Regenerative power limit
0~200%
Model
dependent
☆
P3 V/F Control Parameters
P3-00
V/F curve setting
0: Straight line V / F
1: multi-point V / F
2: square V / F
3: 1.2 Power V / F
4: 1.4 Power V / F
6: 1.6 Power V / F
8: 1.8 power V / F
9: Reserved
10: VF complete separation
mode
11: VF semi-separation mode
0
★
P3-01
Torque boost
0.0%
:(
Ineffective
)
0.1%
~
30.0%
Model
dependent
☆
P3-02
Cut-off frequency of torque
boost
0.00Hz
~
max frequency
50.00Hz
★
P3-03
Multi-point V/F frequency 1
0.00Hz
~
P3-05
0.00Hz
★
Function
Code
Name
Set Range
default
Alteration
P3-04
Multi-point V/F voltage 1
0.0%
~
100.0%
0.0%
★
P3-05
Multi-point V/F frequency 2
P3-03
~
P3-07
0.00Hz
★
P3-06
Multi-point V/F voltage 2
0.0%
~
100.0%
0.0%
★
P3-07
Multi-point V/F frequency 3
P3-05
~
motor rated frequency
(
P1-04
)
0.00Hz
★
P3-08
Multi-point V/F voltage 3
0.0%
~
100.0%
0.0%
★
P3-09
Slip compensation gain
-
-
-
P3-10
V/F over-excitation gain
0
~
200
64
☆
P3-11
V/F oscillation suppression
gain
0
~
100
40
☆