- 27 -
5.1 basic function data
5.1 Data and specifics
Functi
on
Code
Name
Set Range
default
Alteration
P0 Basic Function Group
P0-01
Motor 1 control mode
0: No speed sensor vector
control (SVC)
1: Speed sensor vector control
(FVC)
2: V / F control
2
★
P0-02
Command source selection
0: Operation panel instruction
channel
1: Terminal command channel
2:communication command
channel
0
☆
P0-03
Main frequency reference
setting A channel selection
0: digital setting (preset
frequency P0-08, UP /
DOWN can be modified,
power is not memory)
1: digital setting (preset
frequency P0-08, UP /
DOWN can be modified,
power-down memory
2: AI1 (Note: J4 jumper in the
PANEL and AI1 connected to
the keyboard potentiometer
input, PORT and AI1
connected to the external
terminal AI1 input)
3: AI2
4: AI3
5:High-speed pulse input setting
(S5)
6: multi-segment instructions
7: Simple PLC
8: PID
9: communication given
10: Reserved
2
★
P0-04
Auxiliary frequency source B
command input selection
With P0-03 (main frequency
source A instruction input
selection)
0
★