159
Definition of Communication Parameter Addresses
Read and Written Parameters Function parameters can be read and
written (except those which cannot be changed because they are
only for the factory use or for monitoring).
Parameter group No. and parameter identifying No. are used to
express parameter address.
● High-order bytes: P0 to PF (groups P), A0 to AF (groups A), 70
to 7F (group d)
● Low-order bytes: 00 to FF
For example, to read parameter P3-12, communication address of
F3-12 is expressed as 0xP30C
Note
● Group PF: The parameters cannot be read or changed.
● Group d: These parameters can only be read.
Some parameters cannot be modified when the AC drive is
running. Some parameter cannot be modified regardless of status
of the AC drive. In addition, pay attention to setting range, unit
and description of parameters when modifying them.
Parameter Group
Visited Address
Parameter Address in RAM
P0
~
PE Group
0×F000
~
0×FEFF
0×0000
~
0×0EFF
A0
~
AC Group
0×A000
~
0×ACFF
0×4000
~
0×4CFF
d0 Group
0×7000
~
0×70FF
Notes: Frequent storage to the EEPROM reduces its service life.