4 Robot Instructions
4 - 20
NJ-series NJ Robotics CPU Unit User’s Manual (W539)
Output Variable Update Timing
Output Variables
Name
Meaning
Data type
Valid
range
Description
Done
Done
BOOL
TRUE or
FALSE
TRUE when the settings are completed.
Busy
Executing
BOOL
TRUE or
FALSE
TRUE when the instruction is acknowledged.
CommandAborted
Command
Aborted
BOOL
TRUE or
FALSE
TRUE when the instruction is aborted.
Error
Error
BOOL
TRUE or
FALSE
TRUE while there is an error.
ErrorID
Error Code
WORD
*1
*1. Refer to
for details.
Contains the error code when an error occurs. A
value of 16#0000 indicates normal execution.
Name
Timing for changing to TRUE
Timing for changing to FALSE
Done
When the settings are completed successfully.
• When
Execute
is TRUE and changes to
FALSE.
• After one period when
Execute
is FALSE.
Busy
When
Execute
changes to TRUE.
• When
Done
changes to TRUE.
• When
Error
changes to TRUE.
CommandAborted
• When this instruction is canceled due to an error.
• When this instruction is executed while there is
an error.
• When
Execute
is TRUE and changes to
FALSE.
• After one period when
Execute
is FALSE.
Error
When there is an error in the execution conditions
or input parameters for the instruction.
When the error is cleared.
In-Out Variables
Name
Meaning
Data type
Valid
range
Description
AxesGroup
Axes Group
_sGROUP_REF
---
Specify the axes group.
Содержание NJ501-4300
Страница 13: ...11 CONTENTS NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 40: ...Revision History 38 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 90: ...2 Features of NJ Robotics CPU Unit 2 40 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 204: ...5 Vision Robot Integrated Simulation 5 6 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 308: ...6 Troubleshooting 6 104 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 333: ...I 1 I NJ series NJ Robotics CPU Unit User s Manual W539 Index ...
Страница 335: ......