3 Setting Robot Functions
3 - 14
NJ-series NJ Robotics CPU Unit User’s Manual (W539)
3-5
Checking Wiring from the Sysmac
Studio
This section describes how to check the wiring and electronic gear ratio setting of robot axis.
Use the MC Test Run of the Sysmac Studio or the user program to check the operation.
Refer to the
NJ/NX-series CPU Unit Motion Control User’s Manual
(Cat. No. W507) for how to use the
MC Test Run.
Take the following steps to check the operation.
1
Remove the moving frame if it is attached.
This ensures free movement of each axis.
2
Check the operation.
See the above table for check items. Refer to
Directions of Axis Coordinate System (ACS)
page 2-11 for details on axis operation direction.
3
After you check that all operations are performed as shown in the above table, turn OFF the
Servo for all axes. Attach the moving frame.
Check item
What to check
Check wiring
The wiring for devices such as limit sensors are all correct.
If you give the axis a positive command value, the axis oper-
ates in a downward direction.
Checking electronic
gear settings
The axes moves correctly according to the set angle.
For example, 90
°
.
Содержание NJ501-4300
Страница 13: ...11 CONTENTS NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 40: ...Revision History 38 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 90: ...2 Features of NJ Robotics CPU Unit 2 40 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 204: ...5 Vision Robot Integrated Simulation 5 6 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 308: ...6 Troubleshooting 6 104 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 333: ...I 1 I NJ series NJ Robotics CPU Unit User s Manual W539 Index ...
Страница 335: ......