4 Robot Instructions
4 - 4
NJ-series NJ Robotics CPU Unit User’s Manual (W539)
Precautions for Correct Use
The robot operation stops if any of the following errors occurs during robot operation.
Note that the robot stops immediately in such a case.
• An error that occurs in the MC Function Module.
• An error that occurs in the EtherCAT Master Function Module.
• An error that occurs in the Built-in EtherCAT communications port (hardware).
• An error that occurs in an EtheCAT slave.
While axes operates for a robot instruction, the value of the following output variables of the axes group
is 0.0.
You cannot use these variables for monitoring.
• _MC_GRP[0-31].Cmd.Vel
• _MC_GRP[0-31].Cmd. AccDec
Additional Information
When the robot stops for the MC_Stop (Stop) instruction or an error, the command value for
stopping operation is output to the output variable.
4-1-4
Unusable Output Variables of Axes Group