UM10360_0
© NXP B.V. 2009. All rights reserved.
User manual
Rev. 00.06 — 5 June 2009
607 of 808
NXP Semiconductors
UM10360
Chapter 32: LPC17xx Flash memory interface and programming
8.4 Blank check sector(s)
8.5 Read part identification number
8.6 Read Boot Code version number
Table 574. IAP Blank check sector(s) command
Command
Blank check sector(s)
Input
Command code: 53
10
Param0:
Start Sector Number
Param1:
End Sector Number (should be greater than or equal to start sector
number).
Return Code
CMD_SUCCESS |
BUSY |
SECTOR_NOT_BLANK |
INVALID_SECTOR
Result
Result0:
Offset of the first non blank word location if the Status Code is
SECTOR_NOT_BLANK.
Result1:
Contents of non blank word location.
Description
This command is used to blank check a sector or multiple sectors of on-chip flash
memory. To blank check a single sector use the same "Start" and "End" sector
numbers.
Table 575. IAP Read part identification number command
Command
Read part identification number
Input
Command code: 54
10
Parameters:
None
Return Code
CMD_SUCCESS |
Result
Result0:
Part Identification Number.
Description
This command is used to read the part identification number. The value returned
is the hexadecimal version of the part ID. See
Table 576. IAP Read Boot Code version number command
Command
Read boot code version number
Input
Command code: 55
10
Parameters:
None
Return Code
CMD_SUCCESS |
Result
Result0:
2 bytes of boot code version number in ASCII format. It is to be
interpreted as <byte1(Major)>.<byte0(Minor)>
Description
This command is used to read the boot code version number.