The U1ACR AutoRestart bit can be used to automatically restart baud-rate measurement
if a time-out occurs (the rate measurement counter overflows). If this bit is set the rate
measurement will restart at the next falling edge of the UART1 Rx pin.
The auto-baud function can generate two interrupts.
•
The U1IIR ABTOInt interrupt will get set if the interrupt is enabled (U1IER ABToIntEn
is set and the auto-baud rate measurement counter overflows).
•
The U1IIR ABEOInt interrupt will get set if the interrupt is enabled (U1IER ABEOIntEn
is set and the auto-baud has completed successfully).
The auto-baud interrupts have to be cleared by setting the corresponding U1ACR
ABTOIntClr and ABEOIntEn bits.
Typically the fractional baud-rate generator is disabled (DIVADDVAL = 0) during
auto-baud. However, if the fractional baud-rate generator is enabled (DIVADDVAL > 0), it
is going to impact the measuring of UART1 Rx pin baud-rate, but the value of the U1FDR
register is not going to be modified after rate measurement. Also, when auto-baud is used,
any write to U1DLM and U1DLL registers should be done before U1ACR register write.
The minimum and the maximum baud rates supported by UART1 are function of pclk,
number of data bits, stop bits and parity bits.
(3)
4.15 Auto-baud modes
When the software is expecting an “AT” command, it configures the UART1 with the
expected character format and sets the U1ACR Start bit. The initial values in the divisor
latches U1DLM and U1DLM don‘t care. Because of the “A” or “a” ASCII coding
(”A" = 0x41, “a” = 0x61), the UART1 Rx pin sensed start bit and the LSB of the expected
character are delimited by two falling edges. When the U1ACR Start bit is set, the
auto-baud protocol will execute the following phases:
1. On U1ACR Start bit setting, the baud-rate measurement counter is reset and the
UART1 U1RSR is reset. The U1RSR baud rate is switch to the highest rate.
2. A falling edge on UART1 Rx pin triggers the beginning of the start bit. The rate
measuring counter will start counting pclk cycles optionally pre-scaled by the
fractional baud-rate generator.
3. During the receipt of the start bit, 16 pulses are generated on the RSR baud input with
the frequency of the (fractional baud-rate pre-scaled) UART1 input clock,
guaranteeing the start bit is stored in the U1RSR.
4. During the receipt of the start bit (and the character LSB for mode = 0) the rate
counter will continue incrementing with the pre-scaled UART1 input clock (pclk).
ratemin
2
P
×
CLK
16
215
×
-------------------------
UART
1
baudrate
PCLK
16
2
databits
paritybits
stopbits
+
+
+
(
)
×
------------------------------------------------------------------------------------------------------------
≤
≤
ratemax
=
=