FT DRAFT DRAFT DRAFT DRA
UM10360_0
© NXP B.V. 2009. All rights reserved.
User manual
Rev. 00.06 — 5 June 2009
468 of 808
NXP Semiconductors
UM10360
Chapter 21: LPC17xx Timer 0/1/2/3
6.4 Timer Counter registers (T0TC - T3TC, 0x4000 4008, 0x4000 8008,
0x4009 0008, 0x4009 4008)
The 32-bit Timer Counter register is incremented when the prescale counter reaches its
terminal count. Unless it is reset before reaching its upper limit, the Timer Counter will
count up through the value 0xFFFF FFFF and then wrap back to the value 0x0000 0000.
This event does not cause an interrupt, but a match register can be used to detect an
overflow if needed.
6.5 Prescale register (T0PR - T3PR, 0x4000 400C, 0x4000 800C,
0x4009 000C, 0x4009 400C)
The 32-bit Prescale register specifies the maximum value for the Prescale Counter.
6.6 Prescale Counter register (T0PC - T3PC, 0x4000 4010, 0x4000 8010,
0x4009 0010, 0x4009 4010)
The 32-bit Prescale Counter controls division of PCLK by some constant value before it is
applied to the Timer Counter. This allows control of the relationship of the resolution of the
timer versus the maximum time before the timer overflows. The Prescale Counter is
incremented on every PCLK. When it reaches the value stored in the Prescale register,
the Timer Counter is incremented and the Prescale Counter is reset on the next PCLK.
This causes the Timer Counter to increment on every PCLK when PR = 0, every 2 pclks
when PR = 1, etc.
6.7 Match Registers (MR0 - MR3)
The Match register values are continuously compared to the Timer Counter value. When
the two values are equal, actions can be triggered automatically. The action possibilities
are to generate an interrupt, reset the Timer Counter, or stop the timer. Actions are
controlled by the settings in the MCR register.
3:2
Count
Input
Select
When bits 1:0 in this register are not 00, these bits select
which CAP pin is sampled for clocking.
00
00
CAPn.0 for TIMERn
01
CAPn.1 for TIMERn
10
Reserved
11
Reserved
Note:
If Counter mode is selected for a particular CAPn input
in the TnCTCR, the 3 bits for that input in the Capture
Control Register (TnCCR) must be programmed as 000.
However, capture and/or interrupt can be selected for the
other 3 CAPn inputs in the same timer.
7:4
-
-
Reserved, user software should not write ones to reserved
bits. The value read from a reserved bit is not defined.
NA
Table 409. Count Control Register (T[0/1/2/3]CTCR - addresses 0x4000 4070, 0x4000 8070,
0x4009 0070, 0x4009 4070) bit description
Bit
Symbol
Value
Description
Reset
Value