13
3. Preparation
Digitax SF Instruction Manual
2. System Wiring
Drive
Model
DA2YZ22 DA2Z122 DA21222 DA22422 DA23822
DA24A22
DA26B22 DA28C22
Compatible Motor
M □ 500
M □ 101
M □ 201
M □ 401
M □ 751
M □ 102
M □ 152
MM202
Rated output
50 W
100 W
200 W
400 W
750 W
1 kW
1.5 kW
2 kW
Regeneration
R
esistance 40 Ω to 50 Ω
30 Ω
20 Ω
Allowable
r
egeneration
power
20 W
40 W
60 W
Recommend
e
d Wattage 100 W to 200 W
400 W to 800 W
600 W to
1,200 W
The
braking
resistor
values do not guarantee the optimal performance. Regeneration allowable voltages above
are minimum values as a point of reference.
The
braking
resistor may become very hot. It requires sufficient margin of regeneration allowable power.
When considering a
braking
resistor other than the recommended above, use the following as a guideline.
EMC noise filter
EMC filters prevent emission of electromagnetic interference onto the AC supply lines
.To ensure
compliance with EMC, use the recommended
EMC
noise filter.
OKAYA Electric Industries Co Ltd
AC supply
contactor
This is an on/off switch for the main power supply. Use a surge absorber on the input side of the
AC
supply.
Fuji Electric Co Ltd
Included in
Digitax SF drive
'
s EMC testing.
Select the capacity and other characteristics according to your entire system configuration.
Surge absorber
To ensure compliance with EMC, connect the recommended surge absorber to the primary side of
the AC
supply.
OKAYA Electric Industries Co Ltd
An equivalent product is acceptable.
Select the capacity and other characteristics according to your entire system configuration.
Included in
Digitax SF
drive
'
s EMC testing
Signal line
EMC
noise filter/ferrite core
To ensure compliance with EMC, use the recommended signal line
EMC
noise filter/ferrite core.
SEIWA ELECTRIC MFG. CO., LTD.
(Misumi Corporation)
Included in
Digitax SF
drive
’s EMC testing
Braking
resistor
This product is not equipped with
a braking
resistor. If the smoothing capacitor inside the servo
drive
cannot absorb
the system
regenerative power, an external
braking
resistor is required. As a guideline,
check the regeneration state on the settings panel, and use a
braking
resistor if the regenerative voltage
warning is ON. Build an overheating prevention circuit using a resistor which has built-in thermostat. If the
temperature of generated heat becomes high, you can suppress the heat by installing a cooling device, or
selecting a resistor whose allowable power is 5 to 10 times larger than regenerative voltage.
Chiba Techno Co., Ltd.
For 50 W to 750 W:CAN100S 47 Ω J
100W
For 1 kW, 1.5 kW :CAN400S 30 Ω J
400 W
For 2 kW
:CAN750S 20 Ω J
750 W
Recommended
Product
Recommended
Product
Recommended
Product
Recommended
Product
Recommended
Product
Singlephase:
4200-0056
Threephase:
4200-3106
https://uk.misumiec.com/
SK06G-E10
Single-phase:
2490-2754
Three-phase:
2490-0004
E04SR401938
(ATCK-1130)
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...