26
t
1
3
2
Digitax SF
Instruction Ma
nual
7. Tuning
3. Tuning Parameters
3. Tuning Parameters
1. Tuning
Function
To make the tuning operation easier, select the inertia condition suitable to your
equipment� The inertia conditions that you select will determine the Control Gain 1-2
combination and their ratio�
Parameter
113.1
Position Control Mode: Inertia conditions
Tuning Tip
Prioritize either stability or convergence according to the load and rigidity of your
equipment� Be aware of the trade-off between stability and convergence�
Settings
Intended Use
Effect
1
heavy-load, high fluctuation equipment
low-rigid equipment
robot arms etc�
2
(Default)
(moderate setting)
general transport machines
3
light-load equipment
equipment that demands high-speed
operation or settling-required
Difference in convergence characteristics depending on the inertia condition settings
Speed command value
Position
error
Inertia Condition
Better Stabili
ty
Better Convergence
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...