71
5
Settings
5. Settings
Digitax SF
Instruction Manual
5. Parameters
5.
Parameters
No. 229.0
Quick stop:
Smoothing filter - Moving average counter
Range
Default
Characteristics
1 to 1,000
25
Function
Use
This item
defines the
moving average count of
the
speed command smoothing
filter while the motor is making a quick stop.
The la
r
ger the parameter value, the smoother acceleration/deceleration is and the slower the response.
Motor Capacity
Delay Time Calculation Formula
50 W to 750 W
0.16 [ms]
×(moving average count)=delay time
1 kW to 2 kW
0.2 [ms]
The positioning will take as long as the delay time specified above, set this item within the range
acceptable to the equipment.
Prerequisite
Quick stop: Smoothing filter switch (225.2) = 1 (Enable)
Related To
No. 225.2, No. 239.0
Waveforms for each combination of enable/disable Deceleration Stop and Smoothing Filter.
Deceleration Stop
Disable
Enable
Enable
Smoothing Filter
Disable
Disable
Enable
Command
waveform
No. 232.1
Deceleration stop:
Status during
coast to stop
Settings
Default
Characteristics
0, 1
0
Function
Use
Select on or off for deceleration stop status during
coast to stop
.
Settings
Deceleration stop status
0
OFF (not consider as deceleration stop)
As soon as the servo status becomes OFF, the
motor
brake release (MBRK)
becomes open and the
motor
brake becomes engaged.
With the configuration of No.224.3 (upon servo off) and No.233.3 (upon alarm on),
the
emergency stop
brake release signal (DBRK) immediately turns off and the
emergency stop
brake becomes engaged.
1
ON (consider as deceleration stop)
When the servo state becomes OFF, the deceleration stop status becomes ON.
MBRK remains closed and the
motor
brake remains disengaged until the
deceleration stop status becomes OFF.
With the configuration of No.224.3 (upon servo off) and No.233.3 (upon alarm on),
the
emergency stop
brake release (DBRK) will remain ON and the
emergency stop
brak
e
will remain disengaged until the deceleration stop status becomes OFF.
3
Preparation
Timing Diagrams
-
-
t
t
t
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...