5
4
Connection
Digitax SF
Instruction Manual
2
.
Position Control Mode
4.
Connection
s
2.
Position Control Mode
1: 24 V
24 V
GND
24 V
G24 V
2: G24 V
3: COM+
4: SVON
5: RESET
6: HOLD
7: PCLR
9: CCWL
10: CWL
11: TLSEL1
12: COM-
13: MBRK
14: SERVO
15: POSIN
17: T-LIMIT
18: OCZ
19: SRDY+
20: SRDY-
21: ALM+
22: ALM-
26: CMD_PLS
FG
36: OUT_A
37: /OUT_A
38: OUT_B
39: /OUT_B
40: OUT_Z
41: /OUT_Z
43: 485
44: /485
45: SG
42: SG
27: /CMD_PLS
30: CMD_DIR
31: /CMD_DIR
SG
110
Ω
Control power supply 24 V input
Control power supply GND
I/O power supply 24 V input
INPUT
ȁ
Servo ON
INPUT
䚷
Alarm reset
INPUT
䚷
Command input
inhibition
INPUT
䚷
Error
position
counter
clear
INPUT
䚷
CCW run
limit switch
input
INPUT
䚷
CW run
limit switch
input
I/O power supply GND
OUTPUT
䚷
Motor
Brake
Release
OUTPUT
䚷
Positioning
complete
OUTPUT
䚷
Servo state
OUTPUT Under torque
limit
OUTPUT
䚷
Encoder Z-phase
䠄
open-collector
䠅
OUTPUT
䚷
Servo-Ready+
OUTPUT
䚷
Servo-Ready-
OUTPUT
⅙
Alarm State+
OUTPUT
䚷
Alarm State-
Pulse Train
Command Input
A-phase
output
B-phase
output
Z-phase
output
Pulse
RS-422 output
2 m or
shorter
Twisted Pair Cable
Frame
Encoder Signal Output
Direction
Control Power
Shielded
㻖
3
㻖
1
㻖
1
㻖
1
㻖
1
㻖
2
㻖㻢
㻖
4
㻖
5
Servo
Drive
4.7 k
Ω
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
110
Ω
SG
SG
RS-485
Host Controller
SG
㻖
5
㻖
4
*1) Control power (24V, G24V) and power for I/O (COM+, COM-) must share one common power supply.
*2) When driving a load containing inductance
(
component such as
a
relay
)
connect a protection circuit (diode).
The motor brake cannot be driven directly. Be sure to use a circuit that interfaces with a diode built-in type relay.
Page 46 Connection to general-purpose output signals
*3) The output circuit configuration is an open collector Darlington transistor output. Connects to relays and optical isolators.
Note that when the transistor is on, connector-emitter voltage VCE (SAT) is approximately 1V;
a standard TTL IC does not satisfy VIL and cannot be connected directly.
*4) Be sure to connect a termination resistor of approximately 220 Ω .
*5) Make the connection to the communication IC signal ground of the host controller that
the drive
encoder output signals
are connecting to. Connecting signal ground SG to control power GND may result in malfunction.
*6) If Z-phase pulse width is too small to be measured accurately by the host controller, decrease pulse division rate by using pulse output
ratio (parameters No.276.0 and No.278,0) or decrease rotational speed to increase the pulse width.
Pulse width [ms] = 2 / rotational speed [
rpm
] / (division ratio × 2
17
) × 60 × 1,000.
CN1 Connector Wiring Example
Pulse Train Command, Differential, Standard I/O Configuration
dif.
INPUT Torque limit
selection
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...